Welded titanium tube is strip run through a forming mill, closed with a longitudinal weld under argon, then annealed and sized. We supply it to ASTM…
Welded titanium tube is strip run through a forming mill, closed with a longitudinal weld under argon, then annealed and sized. We supply it to ASTM B338, Grade 1 to 4, 7 and 12, OD 6 to 508 mm, wall 0.5 to 10 mm, bead removed on the OD or on both faces. B862 comes into it only when the item is pipe.
Two things decide whether a welded tube behaves like tube. Penetration is the first. The anneal after welding is the second, and it is the one that gets skipped. A seam that is welded but not annealed stays harder than the parent metal, passes a hydrostatic test, and then splits at the first expansion. Reverse flattening is the test that finds it, which is why B338 asks for it on welded tube.
Bead removal is a duty decision, not a finish option. An ID bead left in place traps product in a line that has to drain or be cleaned in place. An OD bead left proud will not enter the tube hole. Grinding either one thins the wall locally, so the thinning is measured before the tube is released.
A sizing pass after welding brings OD and wall onto tolerance and takes most of the ovality out. Tube that skips it is round enough to look right and out of tolerance at the ends.
| Factor | Seamless | Welded |
|---|---|---|
| Cost per metre | Higher | Lower |
| OD range | 4–114 mm | 6–508 mm |
| Length | Shorter drawn lengths | Long random lengths |
| Thin wall, large OD | Hard to draw | Straightforward |
| Code acceptance | Accepted everywhere | Depends on code and buyer |
| Seam to inspect | None | Must be tested and documented |
From about OD 25 mm upward, welded is normally the cheaper route. The gap for Grade 2 is on request. Below 25 mm it narrows, because weld prep, bead treatment and seam testing cost more per metre than the drawing does. Above roughly 50 mm, with the wall carrying the pressure and the code allowing a seam, the saving is real. In the overlap we quote both and let the drawing decide.
OD 6–508 mm, wall 0.5–10 mm. OD tolerance follows the B338 table, wall is ±10%, ovality stays inside the OD tolerance. Ends are square cut, deburred and capped, or beveled to ASME B16.25 on pipe. Lengths run random 6,000 mm or cut to ±1 mm.
| Item | Detail |
|---|---|
| Pressure test | Hydrostatic at the calculated pressure, or eddy current on the seam |
| Reverse flattening | Opens a weak seam that a pressure test passes |
| MTC | EN 10204 3.1, heat number, chemistry, mechanicals |
| Welding records | WPS and welder qualification on request |
| Item | Detail |
|---|---|
| Packing | ISPM-15 crates with V-supports and capped ends; long lengths in cradles |
| Stock sizes | on request |
| Lead time | on request |
| Minimum order | on request |
Can welded tube go in an exchanger?
Yes, where the design pressure and the customer spec allow it. Welded B338 tube with the ID bead removed is common in larger exchangers. With thin walls and a rolled tube sheet, seamless is still the safer call.
Does the seam need radiography?
Only if the spec asks. Standard release is hydrostatic or eddy current plus reverse flattening. Seam radiography or full-length eddy current can be added, but say so at inquiry because it changes the mill route.
Filler wire for site welding?
Yes, ERTi-2 titanium welding wire in the matching grade, from the same heat where the mill allows it.
Send grade, OD, wall, length, bead condition, test requirement and the code. Choosing between welded and seamless? Send the duty and we price both.
Contact: Jessie
Phone: +86-19539017809
E-mail: sales@gktitanium.com
Add: BLOCK A, HUIHANG PLAZA , HANGTUO ROAD, NATIONAL CIVIL AEROSPACE INDUSTRY BASE, Xi'an