Titanium filler rod in 1 m and 1.5 m straight lengths, Ø1.6 to 4.0 mm, to AWS A5.16 ERTi-1, ERTi-2, ERTi-5 and ERTi-23. Each rod is cut square,…
Titanium filler rod in 1 m and 1.5 m straight lengths, Ø1.6 to 4.0 mm, to AWS A5.16 ERTi-1, ERTi-2, ERTi-5 and ERTi-23. Each rod is cut square, deburred, end-stamped with grade and heat number, colour banded and packed in a capped tube.
| Class | UNS | Base metal | Rm min, annealed | When to choose it |
|---|---|---|---|---|
| ERTi-1 | R50250 | Grade 1 | 240 MPa | Most ductility, post-weld forming |
| ERTi-2 | R50400 | Grade 2 | 345 MPa | Default for CP titanium work |
| ERTi-5 | R56400 | Grade 5 | 895 MPa | Ti-6Al-4V base metal |
| ERTi-23 | R56407 | Grade 23 | 860 MPa | ELI chemistry, implant and cryogenic |
Rod is marked to AWS A5.16, and dual-marked to ISO 24034 where the WPS quotes the ISO designation instead.
| Ø mm (in) | Length | Tolerance | Pack | Pieces |
|---|---|---|---|---|
| 1.6 (0.063) | 1 m / 1.5 m | ±0.02 mm | 1 kg tube | ≈57 |
| 2.0 (0.079) | 1 m / 1.5 m | ±0.02 mm | 1 kg tube | ≈36 |
| 2.4 (0.094) | 1 m / 1.5 m | ±0.03 mm | 2 kg tube | ≈50 |
| 3.2 (0.126) | 1 m / 1.5 m | ±0.03 mm | 2 kg tube | ≈28 |
| 4.0 (0.157) | 1 m / 1.5 m | ±0.03 mm | 2 kg tube | ≈18 |
Piece counts follow the measured lot weight, so they move by one or two either way. Straightness is 1 mm/m and length tolerance is +2/0 mm. Above 4.0 mm, or in 3 m lengths, the rod is quoted rather than stocked.
| End stamp | Grade and heat number struck on one end, still legible on a stub |
| Colour band | Lacquer band near the stamped end, readable at arm's length |
| Tube label | Class, diameter, length, heat number and net weight |
| Neutral supply | Unmarked rod where the customer applies their own identification |
Colour schemes differ between producers, so ours is confirmed on the order rather than assumed. on request A band is a convenience. The stamped heat number is what ties the rod to the certificate, which is why it goes on the end and not only on the tube.
Rod is the same drawing line as our spooled wire, then straightened and cut, so chemistry and tensile match. What it does not have is cast and helix. A straight rod stays where the welder puts it, which is the whole reason hand work still buys rod and not spool.
Wipe the rod with acetone before the first dip, with a cloth kept away from oil. Cut back a contaminated tip rather than dipping it again. Let the rod cool inside the gas shield, and stand open tubes upright in a dry cabinet, because a tube lying on a bench collects exactly what the weld does not want.
| MTC | EN 10204 3.1 with chemistry, mechanicals, hydrogen and heat number |
| Dimensional | Diameter, length and straightness checked per bundle |
| Surface | Checked for die lines and handling marks before packing |
| Item | Detail |
|---|---|
| Tube | Rigid tube, capped both ends, desiccant sachet inside |
| Export case | Carton inside an ISPM-15 plywood case |
| Stock lead time | on request |
| Cut-to-length | on request |
| Minimum order | on request |
1 m or 1.5 m?
Bench and small chamber work usually wants 1 m, because a long rod fouls the work. Tank and field work wants 1.5 m, which keeps the hand further from the arc. Shops doing both order the same heat in both lengths and keep one certificate.
Is this the same as your spooled wire?
Same drawing line and heat, then straightened, cut and end-marked. Chemistry and tensile match. Cast, helix and packing do not.
Can you match our colour code?
Yes, when the quantity supports a separate marking run. Otherwise take our standard banding with the mapping printed on the tube label.
Send class, diameter, length, quantity, and whether the rod needs end stamping or a colour code.
Send Your Requirement · spooled welding wire
Contact: Jessie
Phone: +86-19539017809
E-mail: sales@gktitanium.com
Add: BLOCK A, HUIHANG PLAZA , HANGTUO ROAD, NATIONAL CIVIL AEROSPACE INDUSTRY BASE, Xi'an